Last edited by Guzuru
Tuesday, July 21, 2020 | History

2 edition of Entrainment at a once-through cooling system on western Lake Erie found in the catalog.

Entrainment at a once-through cooling system on western Lake Erie

Richard Allen Cole

Entrainment at a once-through cooling system on western Lake Erie

by Richard Allen Cole

  • 14 Want to read
  • 27 Currently reading

Published by Environmental Protection Agency, Office of Research and Development, Environmental Research Laboratory, for sale by the National Technical Information Service in Duluth, Minn, Springfield, Va .
Written in English

    Subjects:
  • Electric power-plants -- Erie, Lake,
  • Water -- Pollution -- Erie, Lake

  • Edition Notes

    Statementby Richard Allen Cole
    SeriesResearch reporting series
    ContributionsEnvironmental Research Laboratory (Duluth, Minn.)
    The Physical Object
    Paginationv. :
    ID Numbers
    Open LibraryOL13602122M

    The book includes 25 worked-out examples on such items as cyclone pressure drop, entrainment, saltation, riser choking, prilling towers, predicting reaction conversion, viscosity and surface. After cooling to room temperature, the reactants were added through the reactor stem. The feed to catalyst ratio was 5: 1 by weight in all experiments. The reaction pressure (initial) at °C and psig (cold) H, were psig; initial reaction pressures at °C experiments for psig (cold) H, and psig (cold) H, were psig.

    Responsive Documents from the EPA regarding CREW's FOIA request on renewable fuel standards on Thomas M. Pankratz - Environmental Engineering Dictionary and Directory ( CRC Press).pdf код для вставки.

    Industrial Boiler Systems - Free ebook download as PDF File .pdf), Text File .txt) or read book online for free. Fire tube boilers water tube boilers.   A field experiment throughout western Lake Erie is recommended to examine potential benefits of night sampling to management of yellow perch. Published The article is a US Government work and is in the public domain in the USA. Lake Erie Yellow perch age estimation based on three structures: Precision, processing times, and management.


Share this book
You might also like
flora of Algeria

flora of Algeria

The writers workplace

The writers workplace

Babys Bible Friends

Babys Bible Friends

World Book Reading Development Program

World Book Reading Development Program

Global Celebration

Global Celebration

Tony Hillerman

Tony Hillerman

Terrestrial oceans and lunar maria

Terrestrial oceans and lunar maria

Powder Injection Molding Symposium, 1992

Powder Injection Molding Symposium, 1992

Palermo and Monreale..

Palermo and Monreale..

Whiskies galore

Whiskies galore

Commentary on De grammatico

Commentary on De grammatico

[Pedigree of the Swain family] [microform].

[Pedigree of the Swain family] [microform].

decorative art of Russia

decorative art of Russia

Entrainment at a once-through cooling system on western Lake Erie by Richard Allen Cole Download PDF EPUB FB2

EPA/ July ENTRAINMENT AT A ONCE-THROUGH COOLING SYSTEM ON WESTERN LAKE ERIE Volume I by Richard Allen Cole Institute of Water Research and Department of Fisheries and Wildlife Michigan State University East Lansing, Michigan Grant No.

R Project Officer Nelson Thomas Large Lakes Research Station Environmental Research Laboratory. Entrainment at a once-through cooling system on western Lake Erie. Duluth, Minn.: Environmental Protection Agency, Office of Research and Development, Environmental Research Laboratory.

@article{osti_, title = {Impact of a once through cooling system on the yellow perch stock in the western basin of lake erie}, author = {Jensen, A.L. and Hamilton, T.A.}, abstractNote = {Conventional stock assessment models have been applied to determine the impact of entrainment and impingement at the Monroe Power Plant on the yellow perch stock of the western basin of Lake Erie.

Committee on Industrial Arts and Expositions, 3 books National Ocean Survey., 2 books Conference in the Matter of Pollution of Lake Erie and Its Tributaries Cleveland2 books M. Palmer, 2 books Frank H. Quinn, 2 books Robert P Hartley, 2 books Richard Allen Cole, 2 books Great Lakes Laboratory, 2 books L.

Kazimierz Sztramko, 2 books. Jensen, A L, Spigarelli, J A, and Thommes, M M. Use of conventional fishery models to assess entrainment and impingement of three Impact of a once through cooling system on the yellow perch stock in the western basin of lake erie to determine the impact of entrainment and impingement at the Monroe Power Plant on the yellow perch stock.

Great Lakes Res., Internat. Assoc. Great Lakes Res. 5(2) ENTRAINMENT AND IMPINGEMENT OF FISH BY POWER PLANTS IN THE GREAT LAKES WHICH USE THE ONCE-THROUGH COOLING PROCESS John R. Kelso and Gary S. Milburn l Department ofFisheries and Oceans Great Lakes Biolimnology Laboratory Queen Street East Sault Ste.

Marie, Ontario P6A Cited by: The Relationship between Cooling Water Capacity Utilization, Electric Generating EPRI a). The other impact from using a once-through cooling system is caused by the thermal effluent but that is beyond the scope of this paper.

A likely driving factor affecting actual entrainment is the interplay of cooling water use and the. Environmental Research Laboratory (Duluth, Minn.): Entrainment at a once-through cooling system on western Lake Erie / (Duluth, Minn.: Environmental Protection Agency, Office of Research and Development, Environmental Research Laboratory ; Springfield, Va.: [for sale by the] National Technical Information Service, []-), also by Richard A.

The major issue at these once-through cooling power plants was the large water withdrawals at Cayuga and Wabash River Stations [ and cubic feet per second (cfs) maximum plant flows.

These targets are 4 million pounds from Lake Superior, million pounds from Lake Michigan, million pounds from Lake Huron and million pounds from Lake Erie. Lake Ontario has no specific yield objective but has a population objective of million adult fish that produceyearling recruits annually through natural.

The once-through cooling system pumps Chesapeake Bay water at a maximum rate of 73 m3/s (× gallons per min) to the condensers, a total equal to % of the average tidal flow in the area. A once-through cooling system can affect the environment by withdrawing a large amount of water, heating it, adding biocides, and discharging it back to the receiving body.

the Davis-Besse plant on the shore of Lake Erie in north central Ohio, the Beaver Valley plant on the Ohio River in extreme western Pennsylvania, the Trojan Plant on the.

NASA Images Solar System Collection Ames Research Center. Brooklyn Museum. Full text of "Field distribution and entrainment of fish larvae and eggs at the Donald C. Cook Nuclear Power Plant, southeastern Lake Michigan, ".

35 closed-cycle cooling system would be greater than the impacts associated with the existing 36 once-through cooling system, primarily due to construction-stage impacts. The closed-cycle 37 cooling alternative significantly reduces impacts to aquatic ecology, including impacts from 38 entrainment, impingement, and heat shock.

Author: Upaya Created Date: 2/28/ AM. NASA Images Solar System Collection Ames Research Center. Brooklyn Museum. Full text of "Selected water resources abstracts" See other formats.

Richard L. Shilling, P.E., B.S.M., B.E.M.E. Vice President of Engineering, Koch Heat Transfer Company LP; American Society of Mechanical Engineers (Section Editor, Shell-andTube Heat Exchangers, Hairpin/Double-Pipe Heat Exchangers, Air-Cooled Heat Exchangers, Heating and Cooling of Tanks, Fouling and Scaling, Heat Exchangers for Solids, Thermal.

This equates to a percent reduction in flow over a once through cooling system. To better reflect the advances in cooling tower design, EPA now estimates that freshwater cooling towers and saltwater cooling towers reduce impingement mortality and entrainment.

This thesis examines the influence of thermoelectric generation, particularly its nutrient loading effect, on the phytoplankton dynamics in Port Moody Arm (PMA), British Columbia, Canada, a shallow tidal inlet near the city of Vancouver. Spatiotemporal trends of phytoplankton biomass and composition were investigated over a 2 (1/4) year period.

These were related to 'natural' environmental. The JAFNPP ER is provided in accordance with 10 CFRwhich requires license renewal Federal and New York S. The cooling system is a once- through design, in which slightly heated cooling water is returned to Lake Huron after flowing through the main condensers.

It is anticipated that operation of Bruce A Units 1&2 will return the flow and thermal load in the Bruce A discharge to the conditions that existed prior to lay-up.Once-through cooling, on the other hand, is largely by turbulent mixing with ambient water, with less evaporation.

Water short regions often do not have excess water available for consumptive uses. Impoundments built to supply this needed water can often be better used for open cycle cooling in combination with managed sports fisheries.The Water Pollution Control Act has developed into an integrated system to protect our Nation's flowing waters and wetlands Section is an integral part of that protective system.

If this link in the protective web is removed, it will adversely affect the implementation of the act .